Substation Switchgear - Gas Insulated Switchgear (GIS)

ENTEC substation switchgear Gas Insulated Switchgear (GIS) for high purity sf6 gas for 25.8kv gis.

  • Auto Load Transfer Switch function available : Load Transfer time = 1 Cycle
  • High purity SF6 Gas is used for 25.8kV GIS(Gas Insulated Switchgear). This switching device supplies power to the transmission line by connecting to the BANK of substation.
  • Our C-GIS is Cubicle Type and has minimized the use of SF6gas. Operation apparatus life is semi-permanent and maintenance is not necessary by applying PMA method to the operation apparatus. Protects feeder system from the fault ripple effect by safe and quick breaking of fault.

Characteristics

PMA(Permanent Magnetic Actuator) method apply

  • - Reduction of parts compared with current Spring Charge mechanism.
  • - Device structure simplification by parts reduction in operation Mechanism
  • - Reliability increase by Simple Structure => Maintenance Free
  • - Semi-permanent mechanism durability by permanent magnet use => 10000times operation, no need of maintenance

  • (※ 25.8kV GIS Operation device faulty rate during 00~08.04 : 136 of 630 -> 21%
  • Quoted from 2008.08 KEPCO '25.8kV GIS Manufacturing quality improvement Special activity Report')

Cubicle Type GIS(C-GIS)

  • - Minimization of SF6 Gas use
  • - Easy installation, replacement and extension
  • - Minimizing destruction by fault current due to independent structure

Gas Pressure monitoring device and over voltage release device application.

  • - Prevention of accident by Gas rupture
  • - Prevention of 2nd accident by over voltage (Injury or Damage)

High-bright LED apply -> Monitoring of operation and reclosing status. Increase of discernment

Ratings

ENTEC - Electric & Electronics

CEO Greetings | Vision | Hisotry | Awards | Organization | Location | Power Distribution Automation | Metro & Railway System Switchgear | Power Transmission & Distribution | Nuclear Power Plant MOtor Control & Circuit Breaker | LED | Overhead Line SOlid Recloser | SF6 Gas Insulated Recloser | Solid ECO Load Break Switch | SF6 Gas Insulated Polwe Mount Load Break Switch | SF6 Gas Insulated Auto Sectionalizer | Epoxy Insulated Fault Interrupter (EFI)
Underground Line SOlid Insulated Pad Mount Load Break Switch | SF6 Gas Insulated Pad Mount Load Break Switch | Solid Insulated Pad Mount Switchgear | SF6 Insulated Pad Mount Switchgear | Solid Insulated Ring Main (SRMU) | SF6 Gas Insulated 5 & 6 Way Load Break Switch | Compact Secondary Substation | Substation Switchgear Solid Insulated Switchgear (SIS) | Cubicle Type Gas Insulated Switchgear (GIS) | Automatic Load Transfer Switch (ALTS) | Nuclear Power Switchgear DC Circuit Breaker | Q-Class DC Circuit Breaker | Railway DC Switchgear | High Speed Circuit Breaker (HSCB) | DC Disconnector Switch | Silicon Rectifier | Power IT ETSWC101 | ETCPU200 | EasyView | ETPCS-50 | AMR/AMI | EVD - Voltage Detector